Non Relevant Ultrasonic Indications

Image
 Non relevant Ultrasonic Indications can usually be identified as one of the following: Electrical Interference Interference form the transducer (search unit) Interference form the surface of the specimen Interference caused by mode conversion of the sound beam Interference caused by the shape of the specimen Interference caused by material structure Electrical interference can be caused by improper electrical connections of sound energy from the interface between the wedge and test specimen surface. In Immersion Testing, Air bubbles either on the transducer or specimen can cause reduced signal amplitude form the back surface and at times also from the front surface. Surface Interface A small amount of surface wave energy is usually transmitted in all directions around a transducer as shown below. If the transducer is near the edge of a plate, a signal may appear on the CRT.   When inspecting with shear waves, it is possible to detect a surface discontinuity with the small amo...

ISO Standards for Ultrasonic Testing

Image
  Ultrasonic Testing In Ultrasonic Testing we use something called “Ultrasonic Vibrations” we must know two facts about a vibration: A vibration is a back and forth movement. A vibration is energy in motion A depression of a surface from its normal position is called a displacement. Vibrations pass through a solid material as a succession of particle displacements; this can be visualized as shown below: The structure of a material is actually many small particles or groups of atoms. These particles have normal or rest positions and can be displaced from these positions by some force, when the force is removed, the particles will tend to return to their original positions. Energy is transmitted through a solid material by a serious of small material displacements within the material. The transmission of Ultrasonic vibrations through a material is related to the elastic properties of the material. In Ultrasonic Testing a transducer made of Piezo-electric crystals is ...

Sensitivity setting for ultrasonic testing as per ISO 17640

Image
  Range and Sensitivity Setting  for Ultrasonic testing Setting of range and sensitivity shall be carried out prior to each testing in according to this procedure. The temperature difference between the time of range and sensitivity setting and time of test should be within ± 15°C. Checks to confirm these settings shall be performed at least 44 hour once and on completion of tests. The checks should also be done whenever a system parameter is changed. If deviations are found during these checks , corrections given in the below Table. 1 shall be carried out. Reference for Sensitivity Setting for Ultrasonic Testing One of the following technique shall be used for setting of reference Technique 1:  The reference is a Distance Amplitude Curve (DAC) from a dia 3mm side drilled hole. Technique 2:  The references for transverse and longitudinal waves using the distance gain size technique (DGS) based on the diameter of the disk shaped reflector (DSR) are given in the table ...