MAGNETIC PARTICLE TESTING EQUIPMENT

Image
 The following should be considered when selecting equipment for magnetic particle testing. Is equipment for wet or dry method? Magnetization requirements (AC or DC) Demagnetization- incorporated or separate unit? Ampere required. Line voltage requirements. Accessories needed or required. WET HORIZONTAL EQUIPMENT To obtain circular magnetization , the specimen is clamped between the head and tail stocks . For longitudinal magnetization the coil is moved so that the area to be tested is encircled by the coil . A typical wet horizontal unit usually accommodates both AC sand HWDC magnetization . The wet continuous-field method has three basic steps: Flow bath through nozzle and over entire surface of part. Stop bath flow. Apply current at the instant bath flow is stopped. Dry continuous-field method With this method the powder is usually applied from a shaker, bulb, or Blower and follows these steps: Apply magnetizing current. Blow powder parti...