Equipments and materials for NDT lab set up
Equipments and materials for NDT lab set up Radiography Testing: 1) X-Ray tube head -450 kV capacity ( only if construction of a exposure room with approval from government is possible) 2) RT Films (D4 ) 3) lead screen 0.125mm, 0.25 mm 4) Film casettes 5) set of IQI -wire type and hole type, ASTM standards and ISO standard, 6) Lead letters , alphabets and numbers 7) RT weld Film viewers (with intensity control ) 8) Set of developed films 9) Film Densitometer 10 ) Dark room set up for developing, with seperate tenks for Developer, Stoper, Fixer & Rinsing ( only if required) Computed Radiography: Phosphor plate with lead screens and casette CR Scanner and Computer Digital Radiography: Requires a Fixed Digital Radiography Machine Inbuilt X-Ray tube of capacity 150kV upto 400 kV Inbuilt sample positioning system Flat panel detector External control console Computer. ( There are local manufacturers for Digital XRay machine ) Magnetic Particle Testing (MPI): 1) MPI Electromagnetic yoke